Related Products
Product Description
APC Power-Saving Back-UPS Pro 1500 230V - BR1500GI Product Description
BR1500GI
APC Power Saving Back UPS Pro 1500, 230V BR1500GI
Overview
BR1500GI Features
APC Power Saving Back UPS Pro 1500, 230V
High Performance Computer and Electronics UPS for Premium Power Protection
Includes CD with software , Qty 2 Detachable 2.0 m IEC power cords , Telephone Cable , USB cable , User Manual , Warranty card
- Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Audible alarms Provides notification of changing utility power and UPS power conditions
- Automatic self test Periodic battery self test ensures early detection of a battery that needs to be replaced.
- Battery failure notification Provides early warning fault analysis on batteries enabling timely preventive maintenance
- Battery replacement without tools Enables fast battery replacement, lowering Mean Time to Repair MTTR .
- Battery protected and surge only outlets Reserves power capacity and run time for connected equipment that require UPS battery back up while providing surge only protection for less critical equipment
- Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery not available on all models .
- Building Wiring Fault Indicator This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Cold start capable Provides temporary battery power when the utility power is out.
- Dataline surge protection Provides protection of connected equipment from power surges on the data lines.
- Disconnected battery notification Warns when a battery is not available to provide backup power.
- Extendable Run Time Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
- Green mode Patent pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Hot swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
- LCD graphics display Text and mimic diagrams that display modes of operation, system parameters and alarms.
- Power saving outlets Automatically cuts power to idle equipment to conserve electricity.
- Resettable circuit breaker Easy recovery from overloads no need to replace a fuse.
- Safety agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Serial connectivity Provides management of the UPS via a serial port.
- Telephone dataline surge protection Provides protection of connected equipment from power surges traveling on telephone lines.
- Transformer block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles.
- USB connectivity Provides management of the UPS via a USB port not available on all models .
- User replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR
Back UPS Pro Features Benefits
Safety
- Safety agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Boost Automatic Voltage Regulation AVR Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
- Energy Management Function Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
- Green mode Patent pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- LCD Status Display Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
- Battery protected and surge only outlets Reserves power capacity and run time for connected equipment that require UPS battery back up while providing surge only protection for less critical equipment
- Battery and surge protected outlets Back up and protect your hardware and data during power outages, surges and spikes.
- Surge only outlets Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
- Dataline surge protection Provides protection of connected equipment from power surges on the data lines.
- Transformer block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles.
- Energy Management Function Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
- Green mode Patent pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery not available on all models .
- Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Cold start capable Provides temporary battery power when the utility power is out.
- Customizable voltage transfer points Adjust the voltage points widen or tighten the range where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
- Customizable voltage sensitivity Toggle between pre determined voltage transfer points depending on your power quality high, medium or low sensitivity , maximizing useful battery life and protecting sensitive electronics.
- Battery failure notification Provides early warning fault analysis on batteries enabling timely preventive maintenance
- Automatic self test Periodic battery self test ensures early detection of a battery that needs to be replaced.
- Simple battery replacement Increases UPS availability by allowing quick, easy battery replacement.
- Resettable circuit breaker Easy recovery from overloads no need to replace a fuse.
- Audible alarms Provides notification of changing utility power and UPS power conditions
- LCD Status Display Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
- USB connection Use your PC to access additional power protection and management features for your UPS via a USB Port.
- Disconnected battery notification Warns when a battery is not available to provide backup power.
Specifications
Output | |
Load Crest Factor | 3 1 |
Output Frequency sync to mains | 50/60Hz / 3 Hz |
Output Connections | 5 IEC 320 C13 Battery Backup 5 IEC 320 C13 selector surgetitle |
Max Configurable Power Watts | 865 Watts / 1.5 kVA |
Output power capacity | 865 Watts / 1.5 kVA |
Topology | Line Interactive |
Waveform type | Stepped approximation to a sinewave |
Transfer Time | 10ms typical 12ms maximum |
Input | |
Number of Power Cords | 2 |
Input frequency | 50/60 Hz / 3 Hz auto sensing |
Input voltage adjustable range for mains operation | 156 300 V |
Input voltage range for main operations | 176 294 V |
Input Breaker Capacity | 10 A |
Input Connections | IEC 320 C14 |
Battery | |
Typical recharge time | 8 hour s |
Battery type | Maintenance free sealed Lead Acid battery with suspended electrolyte leakproof |
RBC Quantity | 1 |
Battery Volt Amp Hour Capacity | 187 |
Runtime | |
Communication | |
Audible Alarm | Alarm when on battery distinctive low battery alarm overload continuous tone alarm |
Control panel | Multi function LCD status and control console |
Runtime | |
Output power capacity | 865 Watts / 1.5 kVA |
Surge | |
Data Line Protection | Analog phone line for phone/fax/modem/DSL RJ 11 connector , Network line 10/100/1000 Base T Ethernet RJ 45 connector |
Filtering | Full time multi pole noise filtering 10% of IEEE surge let thgouh zero clamping response time instantaneous |
Physical | |
Color | Black |
Maximum Depth | 380 mm , 38.0 CM |
Maximum Height | 301 mm , 30.1 CM |
Net Weight | 12.7 KG |
Maximum Width | 112 mm , 11.2 CM |
Environmental | |
Audible noise at 1 meter from surface of unit | 45.0 dBA |
Operating Temperature | 0 40 C |
Operating Elevation | 0 9000 meters |
Operating Relative Humidity | 0 95 % |
Storage Temperature | 15 45 C |
Storage Elevation | 0 15000 meters |
Storage Relative Humidity | 0 95 % |
Conformance | |
Approvals | A tick, C tick, CE, GOST, GS Mark, Telepermit, TUV |
Standard warranty | 2 years repair or replace |
Sustainable Offer Status | |
RoHS | Compliant |
REACH | REACH Contains No SVHCs |
Customer Reviews
Loading