Related Products
Product Description
APC Smart-UPS RT 20kVA RM 230V - SURT20KRMXLI Product Description
SURT20KRMXLI
APC Smart UPS RT 20kVA RM 230V SURT20KRMXLI
SURT20KRMXLIFeaturesAPC Smart UPS RT 20kVA RM 230V
- Dual mains input Increases availability by allowing the UPS to be connected to 2 separate power sources.
- LCD display Alpha Numeric Display which displays system parameters and alarms.
- Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
- Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack mount environment.
- Removable input/output wiring tray Allows quick and easy installation and maintenance of the UPS.
- Single or 3 phase input wireable Provides flexibility for the UPS to be installed using either single or 3 phase input wiring.
- Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
- Scalable runtime Allows additional run time to be quickly added as needed.
- Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Hot swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
- Temperature compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
- Network manageable Provides remote power management of the UPS over the network.
- InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
- SmartSlot Customize UPS capabilities with management cards.
- LED status indicators Quickly understand unit and power status with visual indicators.
- Serial connectivity Provides management of the UPS via a serial port.
- Automatic self test Periodic battery self test ensures early detection of a battery that needs to be replaced.
- Predicitive failure notification Provides early warning fault analysis ensuring proactive component replacement.
- User replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR
- Disconnected battery notification Warns when a battery is not available to provide backup power.
- Audible alarms Provides notification of changing utility power and UPS power conditions
- Plug and Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
- Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack mount environment.
- Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
- Resettable circuit breaker Easy recovery from overloads no need to replace a fuse.
- Safety agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
- Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Cold start capable Provides temporary battery power when the utility power is out.
- Save time with easy and convenient remote accessibility. Network manageable via serial, USB or optional Ethernet. Includes Powerchute Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
- Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
- Low operating and maintenance costs with proven reliability and intelligent battery management. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot swappable battery modules provide battery replacement without powering down.
- Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected PFC power supplies. Safety agency tested and approved means that you can deploy Smart UPS with confidence that they meet or exceed the industry s most rigorous standards.
Specifications
Output- Output power capacity
16.0 KWatts / 20.0 kVA - Max Configurable Power Watts
16.0 KWatts / 20.0 kVA - Nominal Output Voltage
230V - Output Voltage Note
Configurable for 400 or 415V 3 Phase nominal output voltage - Output Voltage Distortion
Less than 5% - Output Frequency sync to mains
50/60 Hz / 3 Hz user adjustable / 0.1 - Other Output Voltages
220, 240 - Load Crest Factor
3 1 - Topology
Double Conversion Online - Waveform type
Sine wave - Overload Operation
60 seconds 125% and 30 seconds 150% - Output Connections 2 IEC Jumpers Battery Backup 8 IEC 320 C19 Battery Backup 1 Hard Wire 3 wire H N G Battery Backup
- Bypass
Built in Static Bypass, Internal Bypass Automatic and Manual , Optional External Bypass
- Nominal Input Voltage
230V , 400V 3PH - Input frequency
40 70 Hz auto sensing - Input Connections
Hard Wire 3 wire 1PH N G , Hard Wire 5 wire 3PH N G - Input voltage range for main operations
160 280V - Input Total Harmonic Distortion
Less than 5% for full load - Other Input Voltages
220, 240 - Maximum Input Current
115.0A - Input Power Factor at Full Load
0.98
- Battery type
Maintenance free sealed Lead Acid battery with suspended electrolyte leakproof - Included Battery Modules
4 - Typical recharge time
2.5hour s - Nominal Battery Voltage
/ 192 V split battery referenced to neutral - Replacement Battery APCRBC140
- Expected Battery Life years
3 5 - RBC Quantity
4 - Extendable Run Time
1 - Battery Volt Amp Hour Capacity
3840 - Extended Run Options APC Smart UPS RT 20kVA RM 230V
- End of Discharge Battery Voltage
/ 154 V - Efficiency in Battery Operation
93.0 % - Runtime View Runtime Graph View Runtime Chart
- Efficiency View Efficiency Graph
- Interface Port s
DB 9 RS 232 , RJ 45 10/100 Base T , Smart Slot - Pre Installed SmartSlot Cards AP9631
- Control panel
Multi function LCD status and control console - Audible Alarm
Audible and visible alarms configurable delays - Emergency Power Off EPO
Yes
- Filtering
Full time multi pole noise filtering 0.3% IEEE surge let through zero clamping response time meets UL 1449
- Maximum Height
533mm , 53.3cm - Maximum Width
432mm , 43.2cm - Maximum Depth
773mm , 77.3cm - Rack Height
12U - Net Weight
247.73kg - Shipping weight
314.09kg - Shipping Height
990mm , 99.0cm - Shipping Width
610mm , 61.0cm - Shipping Depth
1003mm , 100.3cm - Color
Black - Units per Pallet
1.0
- Operating Environment
0 40 C - Operating Relative Humidity
0 95% non condensing % - Operating Elevation
0 3000meters - Storage Temperature
15 45 C - Storage Relative Humidity
0 95% non condensing % - Storage Elevation
0 15000meters - Audible noise at 1 meter from surface of unit
59.0dBA - Online thermal dissipation
3770.0BTU/hr - Protection Class
IP 20
- Approvals
BSMI, EN/IEC 62040 2, EN/IEC 62040 1 1, VDE - Standard warranty
2 years repair or replace
- RoHS
Compliant - REACH
REACH Contains No SVHCs - PEP
Available in Documentation tab - EOLI
Available in Documentation tab - Battery Directive
Compliant - Battery Notes
ts Battery Notes
Customer Reviews